Jump to information

Victorum Compact Exhaust Air Heat Pump

FEATURES & BENIFITS

A Victorum EAHP system Combines the aspects of both a conventional air source heat pump and a mechanical extract ventilation system (MEV) to provide 100% of the space heating requirements and DHW demand for a well-insulated apartment unit. Ensuring compliance with domestic ventilation regulations and working efficiently can reduce your home’s energy consumption for heating by up to 50% compared to conventional heating systems. Unlike the Victorum pre-plumb version this range is all cased within a single sleek white casing. The unit can be moved around in 2 pieces and assembled when in its final location.

Click Here to see our alternate air to water heat pump options.

  • All in one compact white cased design
  • Standalone heating, hot water & ventilation system
  • Satisfies 100% of heating and hot water demand
  • Whole house mechanical extract ventilation (MEV)
  • Energy recycled from the apartment
  • Full compliance with Part L and SAP using an all-electric solution

Design Team & Support Service

Joule’s team of inhouse building services engineers provide free of charge layout drawings for the project. Both ventilation and LTWH layout drawings and schematics are supplied as part of our overall service. We will also attend any design team and site meetings as it required during the project. Our team of service and commissioning engineers are  on hand to provide support with regard to installation queries and commissioning and handover. Click on the below to view a sample dwelling drawing for this product.

Electrical

The Victorum compact unit requires one power supply. The heatpump requires a 32amp breaker with a localised isolator switch. If the unit is not been fitted with a central BMS it requires a 2 core shielded flex cable from the unit to an outside location for the mounting of the external temp sensor. This sensor should not be mounted in a location that is exposed to direct sunlight if at all possible. The system is controlled by its own room thermostat that is ideally located in the living room of the dwelling. This will always be the case unless the dwelling is been heated by underfloor heating in which case the heatpump thermostat will be left with the heatpump and the homeowner will control the heating system using the underfloor heating thermostats. If the heatpump thermostat is been used a Belden cable of spec 8723 type along with a 2 core flex cable should be fitted between the heatpump and stat location.

Mechanical

The Victorum compact system is a sleek white cased system that assembles into a single piece like a fridge. The unit comes in 2 pieces to allow for easy movement and installation. It can come in one or two heating zones. As with all heatpumps flow rates are a consideration. Correct filling and balancing of the system are required to ensure perfect operation. 10mm or microbore pipework should not be used. Flush carts rather than mains connected filling loops should be used to correctly flush and purge the system. Each radiator or underfloor heating circuit needs to be purged in isolation.

Ducting

The unit is a central mechanical extract ventilation system. This means it extracts from the wet rooms and dumps the waste air outside. The supply air is done passively through ducted valves in the habitable rooms. Each extract valve in the wet rooms should be connected to a 204x60mm flat-pack duct and when 2 or more valves are joined together the flat-pack duct should increase to 220x90mm. for dwellings within the capacity range of the Victorum, there will seldom be a requirement to go to any larger ducting. Circular ducting can also be used. Joule provides ducting layout drawings for different dwelling types within the development. Consideration should always be given for ducting crossing fire zones. The supply ducting should be 204x60mm and serve individual supply valves in each relevant room.

Victorum EAHP Specification

Item Number

HHH-3-0000-VHP

Total Heating Capacity

5 Kw

Total Compressor Output

2 Kw

Max Circuit Amps (MCA)

28A

Max Fuse Amps (MFA)

32A

COP (A20, W35)

4.9

Refrigerant

R 134a

Max Flow Temperature

60°C

Max Vent Flow Rate Heating:

100-250m3/h

Ventilation Rate Speed

50-350 m3/h

Height:

2100mm

Width:

592mm

Depth:

672mm

Weight:

45kg

Air Inlet/ Outlet Connections:

150mm

Certifications:

For Space Heating

I.S. EN 14825

For Hot Water

I.S EN 16147

Test Conditions

I.S EN 14511

Cyclone Cylinder Specification
Capacity / Item No


180L

TUVI2C-180-L2C

TUVI2C-180-L3C

Cylinder Material

Stainless Steel Duplex LDX 2101

Thermal Insulation Thermal Insulation Polyurethane foam CFC-Free & HCFC Free
Coil Material

Stainless Steel Tube AISI 316L

Weight (empty) kg

47 kg

Weight (full) kg

244 kg

Max. Operating Pressure

5 (bar)

Test Pressure

10 (bar)

Max. Working Temperature

90 c

Heating Elements

1. No. Incoloy Immersion

Heat Loss

81 W

Energy Efficiency Class C C

Matthew Nicholson

Area Sales Rep

Mob: 087 454 8155

Email: matthew@joule.ie

Darren Moran

Area Sales Rep

Mob: 087 656 3613

Email: darrenmoran@joule.ie

Ciaran Clohessy

Area Sales Rep

Mob: 087 357 6408

Email: ciaran@joule.ie

Eoin Naughton

Area Sales Manager

Mob: 086 773 5095

Email: eoin@joule.ie

Sean Collins

Area Sales Rep

Mob: 087 692 8114

Email: sean@joule.ie

Eoghan Conway

Area Sales Rep

Mob: 083 176 2372

Email: eoghan@joule.ie

Ronan Ginnell

Group MD

Mob: 077302 17060

Email: ronan@jouleuk.co.uk

Frazer Dalrymple

Area Sales Manager

Mob: 07525 279840

Email: frazer.dalrymple@jouleuk.co.uk

Andrea Innes

Area Sales Manager

Mob: 07764 961624

Email: andrea.innes@jouleuk.co.uk

Craig McCrudden

Area Sales Manager

Mob: 07495 580932

Email: craig@jouleuk.co.uk

Paul Steward

Renewable Sales Manager

Mob: 07506 194540

Email: paul@jouleuk.co.uk

Rob Chalkley

Area Sales Manager

Mob: 07983 686720

Email: robert@jouleuk.co.uk