Jump to information

Victorum Pre Plumb Exhaust Air Heat Pump System

FEATURES & BENIFITS

A Victorum EAHP system Combines the aspects of both a conventional air source heat pump and a mechanical extract ventilation system (MEV) to provide 100% of the space heating requirements and DHW demand for a well-insulated apartment unit. Ensuring compliance with domestic ventilation regulations and working efficiently can reduce your home’s energy consumption for heating by up to 50% compared to conventional heating systems.

Click Here to see our alternate air to water heat pump options.

  • Standalone heating, hot water & ventilation system
  • Satisfies 100% of heating and hot water demand
  • Whole house mechanical extract ventilation (MEV)
  • Energy recycled from the apartment
  • Full compliance with Part L and SAP using an all-electric solution

Design Team & Support Service

Joule’s team of inhouse building services engineers provide free of charge layout drawings for the project. Both ventilation and LTWH layout drawings and schematics are supplied as part of our overall service. We will also attend any design team and site meetings as it required during the project. Our team of service and commissioning engineers are  on hand to provide support with regard to installation queries and commissioning and handover. Click on the below to view a sample dwelling drawing for this product.

BIMS

Our detailed EAHP range of BIM families are available to start working into 3D building information modelling programs such as Autodesk REVIT. BIM modelling enables better project planning and thereby ensures accuracy. It will provide accurate cost estimates for early project certainty enhances operations, maintenance, and facility management.

FIRST FIX DETAILS

The Victorum unit is designed to be wall mounted. Careful consideration must always be given to any mechanical plant mounted on a wall. With this in mind we have specified a specific wall build up to ensure secure mounting. The Victorum should never be mounted on a wall backing onto a bedroom. The unit ideally should be mounted to a precast concrete wall or a rigid stiff partition wall. If mounted on a partition wall this should be supported locally using timber studs. The studs should allow for flex in the floors. This partition should then be covered with ¾” MDF sheeting. The correct supplied mounting system should be used to fix the unit in place. Click on the below download to see the exact detail.

ELECTRICAL

The Victorum unit requires two power supplies. The first for the heatpump and the second for the preplumb cylinder. The heatpump requires a 13amp fused spur and the cylinder requires a 32amp switch. If the unit is not been fitted with a central BMS it requires a 2 core shielded flex cable from the cylinder to an outside location for the mounting of the external temp sensor. This sensor should not be mounted in a location that is exposed to direct sunlight if at all possible. The system is controlled by its own room thermostat that is ideally located in the living room of the dwelling. This will always be the case unless the dwelling is been heated by underfloor heating in which case the heatpump thermostat will be left with the heatpump and the homeowner will control the heating system using the underfloor heating thermostats. If the heatpump thermostat is been used a Belden cable of spec  should be fitted between the heatpump and stat location. If the heatpump thermostat is been used a Belden cable of spec 8723 type along with a 2 core flex cable should be fitted between the heatpump and stat location.

MECHANICAL

The Victorum system is similar to a traditional HIU or gas boiler wet heating system. It can come in one or two heating zones. As with all heatpumps flow rates are a consideration. Correct filling and balancing of the system is required to ensure perfect operation. 10mm or microbore pipework should not be used. Flush carts rather than mains connected filling loops should be used to correctly flush and purge the system. Each radiator or underfloor heating circuit needs to be purged in isolation.

DUCTING OPTIONS

The unit is a central mechanical extract ventilation system. This means it extracts from the wet rooms and dumps the waste air outside. The supply air is done passively through ducted valves in the habitable rooms. Each extract valve in the wet rooms should be connected to a 204x60mm flat pack duct and when 2 or more valves are joined together the flat pack duct should increase to 220x90mm. for dwellings within the capacity range of the Victorum there will seldom be a requirement to go to any larger ducting. Circular ducting can also be used. Joule provides ducting layout drawings for different dwelling types within the development. Consideration should always be given for ducting crossing fire zones. The supply ducting should be 204x60mm and serve individual supply valves in each relevant room.

Product Specifications

Cyclone Cylinder Specifications
Capacity 200L 250L
TUVI-3-200-L2C TUVI-2-250-L2C
TUVI-3-200-L3C TUVI-2-250-L3C
Cylinder Material Stainless Steel / Duplex LDX 2101
Thermal Insulation Polyurethane foam CFC-Free & HCFC Free
Casing Painted Galvanised Carbon Steel DX51D
Coil Material Stainless Steel Tube AISI 316L
Weight (empty) kg 59 kg 69 kg
Weight (full) kg 256kg 315 kg
Max. Operating Pressure 5 (bar)
Test Pressure 10 (bar)
Max. Working Temperature 90 c
Heating Elements 1. No. Incoloy Immersion
Heat Loss 78 W 87 W
Heat up Time (mins) 31 37
Energy Efficiency Class C C C
Height (mm) 1490mm 1405mm
Victorum EAHP Specification
Item Number HHH-2-0000-VHP
Total Heating Capacity 5 Kw
Total Compressor Output 2 Kw
Max Circuit Amps (MCA) 28A
Max Fuse Amps (MFA) 32A
COP (A20, W35) 4.9
Refrigerant R 134a
Max Flow Temperature 60°C
Max Vent Flow Rate Heating: 100-250m3/h
Ventilation Rate Speed 1, 2, 3 50-350 m3/h
Height: 570mm
Width: 500mm
Depth: 500mm
Weight: 45kg
Unit Connections: 15mm
Air Inlet/ Outlet Connections: 150mm
Certifications:
For Space Heating I.S. EN 14825
For Hot Water I.S EN 16147
Test Conditions I.S EN 14511

Matthew Nicholson

Area Sales Rep

Mob: 087 454 8155

Email: matthew@joule.ie

Darren Moran

Area Sales Rep

Mob: 087 656 3613

Email: darrenmoran@joule.ie

Ciaran Clohessy

Area Sales Rep

Mob: 087 357 6408

Email: ciaran@joule.ie

Eoin Naughton

Area Sales Manager

Mob: 086 773 5095

Email: eoin@joule.ie

Sean Collins

Area Sales Rep

Mob: 087 692 8114

Email: sean@joule.ie

Eoghan Conway

Area Sales Rep

Mob: 083 176 2372

Email: eoghan@joule.ie

Ronan Ginnell

Group MD

Mob: 077302 17060

Email: ronan@jouleuk.co.uk

Frazer Dalrymple

Area Sales Manager

Mob: 07525 279840

Email: frazer.dalrymple@jouleuk.co.uk

Andrea Innes

Area Sales Manager

Mob: 07764 961624

Email: andrea.innes@jouleuk.co.uk

Craig McCrudden

Area Sales Manager

Mob: 07495 580932

Email: craig@jouleuk.co.uk

Paul Steward

Renewable Sales Manager

Mob: 07506 194540

Email: paul@jouleuk.co.uk

Rob Chalkley

Area Sales Manager

Mob: 07983 686720

Email: robert@jouleuk.co.uk